How to Keep a Well Pump From Freezing: A Winter Protection Guide

How to Keep a Well Pump From Freezing: A Winter Protection Guide

Protect the parts of your well system that hold water above the frost line. Keep an above-ground jet pump, pressure tank and pressure switch piping in an insulated, draft-sealed space with a thermostat-controlled heater rated for the location. Insulate exposed pipes and use approved heat cable where needed. A submersible pump deep in the well is usually protected, but the switch, tank and piping near the wellhead can still freeze.

This guide covers which parts are most vulnerable, how to prepare for cold weather and what to do if you wake up to no water. If you need a replacement, browse the Sta-Rite jet pumps in our well pump collection.

Which Well Setups Freeze (and Which Usually Don't)

Water expands as it freezes. A pipe, fitting or pump casing can crack if it holds water in an unheated space. Use the table to identify the parts of your system that need protection.

Setup

Where the pump sits

What usually freezes

Risk level

Shallow well jet pump

Above ground, in a pump house, crawl space, or basement

Pump casing, suction line, pressure switch tube, tank, piping

High if the space is unheated

Deep well or convertible jet pump

Above ground, often right over or next to the well

Same as shallow jet, plus the drive and suction pipes near the wellhead

High if the space is unheated

Submersible pump

Down in the well, below the frost line

Pressure switch and its tube, tank, above-ground piping, a pitless adapter installed too shallow

Moderate, mostly the above-ground parts

Booster or pressure pump

Indoors or in an equipment room

Exposed supply lines, the tank, the switch

Low if the room is heated

If you are not sure which type you have, our guide to jet pumps vs submersible pumps explains how to tell them apart. A jet pump is a visible motor and pump body above ground. A submersible system typically shows only a pressure tank, a switch, and a well cap.

Submersibles still have weak points

A properly installed pitless adapter routes water out of the casing below the local frost line. The tank, pressure switch and any aboveground piping still need protection, even when the pump itself sits deep in the well.

The Part That Freezes First: The Pressure Switch Tube

The narrow fitting that feeds the pressure switch is a common freeze point. The Water Systems Council identifies it as an area to protect. If ice blocks the fitting, the switch may fail to sense system pressure. The pump may then fail to start or keep running after pressure has risen.

Insulate this fitting, keep it inside the heated envelope, and check it first any time you lose water on a cold morning.

How to Winterize a Well Pump: 6 Prevention Steps

1. Build or upgrade an insulated pump house

Insulate the walls, roof and door. Check the floor and gaps along the slab, where drafts can enter. Leave enough room to service the equipment and maintain the airflow and clearances specified for the motor and heater.

2. Seal drafts

Seal drafts around pipe penetrations and doors. Use weatherstripping where it helps, and keep any ventilation the equipment requires.

3. Add a thermostat-controlled heat source rated for the space

A well house heater should be thermostatically controlled and listed for the size and type of space you are heating. The Water Systems Council recommends keeping an above-ground pump where it stays above 40°F, so set the thermostat with some margin. Follow the heater manual for clearances, mount it away from water spray, and keep it away from insulation, cardboard, and anything else that can burn.

  • Use a heater with a built-in thermostat or plug it into a listed thermostat controller.
  • Put the heater on a circuit that can handle the load alongside the pump.
  • Add a low-temperature alarm or a remote thermometer so you know before pipes freeze.
  • Avoid relying on a single incandescent bulb in a large or drafty space.

4. Use heat tape the right way

Heat tape (heat cable) is a good fix for exposed runs, but install it exactly as the manufacturer directs. Choose a UL-listed product labeled for your pipe's material, diameter, and length. The U.S. Consumer Product Safety Commission warns against overlapping tape unless the instructions allow it and against covering it with insulation unless the manufacturer recommends it. Use the ground-fault protection the instructions call for, and inspect the full length every fall for cracks, charring, or bare wire.

5. Insulate exposed pipes

Wrap every above-ground line with foam pipe insulation, including the suction pipe on a jet pump, the line from the wellhead, and the discharge to the house. Buried lines should run below your local frost depth. If a line has frozen more than once, it is likely too shallow or exposed to wind.

6. Plan for power outages

Plan ahead for extended outages. A properly installed backup power system can keep the pump and heater running. If you cannot maintain heat, follow the pump and tank manuals for shutting off power, relieving pressure and draining the equipment.

Why Running Water Is Not a Fix for a Pump House

A dripping faucet provides limited protection to the pipe carrying the flow. The pump cycles as pressure changes, leaving other parts of the system exposed to cold between cycles. Use insulation and a reliable heat source to protect the equipment.

Need a Replacement Jet Pump Before the Next Cold Snap?

Call the ePumps team at (844) 378-6771 to match horsepower, well depth, and voltage, or browse our shallow well pumps and deep well jet pumps.

What to Do If Your Well Pump Froze

If you lose water during freezing weather, ice may be blocking a line or a fitting. Shut the system down before checking for damage.

  1. Shut off the pump at the breaker before checking the equipment. Leave work on the pressure switch, wiring or motor to a qualified technician.
  2. Do not run the pump while it is frozen. Ice blocking the discharge can make the pump run against a closed outlet, and Sta-Rite warns this can boil water inside the pump. Ice in the suction side can run it dry, which damages the seal.
  3. Find the frozen section. Check the pressure switch tube, the pump casing, and exposed piping first. Frost on the outside of a pipe is a good clue.
  4. Warm the affected area gradually. If you can reach a frozen pipe safely, use warm towels or another gentle method appropriate for the pipe. Keep electrical equipment away from standing water and never use an open flame.
  5. Inspect before restoring power. Look for a cracked pump casing, split fittings, a bulged or cracked pressure switch base, and leaks at the tank. Check that the pressure switch tube is clear.
  6. Once the system has thawed and you have ruled out visible damage, follow the manufacturer’s restart instructions. Confirm the pump builds pressure and shuts off at its cut-out setting. If a jet pump needs to be primed again, see our guide on why a pump loses prime.

If water is spraying, the pump hums without pumping, or pressure will not come back up, shut it down and see our post on why a well pump loses pressure before running it again.

Damage Checklist After a Freeze

  • Cracked pump casing: cast iron jet pump bodies can split along a seam. A cracked casing usually means replacement.
  • Pressure switch: a frozen tube can crack the switch base or leave the contacts stuck. Replace if it does not cycle cleanly.
  • Pressure tank: check for leaks and recheck the precharge with the tank drained. Our pressure tank sizing guide explains how to set it.
  • Fittings and check valves: look for split threads and leaks around unions.
  • Motor: listen for hum without rotation, which can point to a seized impeller or a damaged start component.

For a broader list of symptoms, see 8 warning signs your well pump is going bad. Note that Sta-Rite's manual warns that letting the pump or any system component freeze voids the warranty, so prevention matters.

When to Replace the Pump and How to Match It

A thawed pump that runs normally can go back into service. A cracked casing, a seized motor, or repeated freeze damage usually means it is time to replace. Our repair vs replace guide helps you weigh the call. When you replace, match these four things.

Match this

Why it matters

Where to find it

Pump type

Shallow well jet pumps lift water from about 25 feet or less. Deeper wells need a convertible or deep well jet, or a submersible.

Your well depth and pumping water level

Horsepower and flow

Too small and pressure suffers. Too large and the pump short cycles.

Old nameplate, plus the 1 HP vs 2 HP well pump guide

Voltage

Many jet pumps are dual voltage (115/230V) and must be wired for your supply.

Nameplate and your breaker

Piping

Suction, drive, and discharge sizes (for example 1-1/4 in. suction and 1 in. discharge) and single-pipe vs double-pipe deep well setups.

Existing plumbing and the product spec

ePumps carries Sta-Rite shallow well jet pumps in 1/2, 3/4, and 1 HP, plus convertible and multi-stage deep well jet pumps from 1/2 to 2 HP. Several, such as the Sta-Rite HND 3/4 HP shallow well jet pump, include a drain port that makes winterizing easier. You can compare them all in the Sta-Rite pumps collection, or start with our best well pump picks.

Final Thoughts

Focus on the pump house, the pressure switch fitting and exposed piping. If the system freezes, shut off power and inspect it after thawing before restarting. If pressure remains low, use our low water pressure checklist to narrow down the cause.

Frequently Asked Questions

How do I keep my well pump from freezing without electricity?

Insulation and draft sealing slow heat loss during a short outage. For a longer outage, use a properly installed backup power system or follow the equipment manuals for shutting down, depressurizing and draining the system.

What temperature does a well pump freeze?

Water freezes at 32°F. The Water Systems Council recommends keeping the area around an aboveground pump above 40°F to leave a margin for cold spots and drafts.

Can a frozen well pump fix itself?

A frozen line often thaws on its own when temperatures rise, but the damage may already be done. Keep the power off until it thaws, then inspect the casing, switch, and fittings for cracks before restarting.

Do submersible well pumps freeze?

The submersible pump itself rarely freezes because it sits below the frost line. The pressure switch and its tube, the pressure tank, exposed piping, and a pitless adapter installed too shallow can all still freeze.

Talk to a Well Pump Specialist

Not sure which replacement fits your well? Call (844) 378-6771 or contact our customer service team, and browse all well pumps in stock.