Start with the flow and head your boiler requires. Use those figures to select a Grundfos CR pump size and stage count. Before ordering, check shutoff pressure, suction conditions at operating temperature, and whether CR, CRI, or CRN materials suit your feedwater.
The Grundfos CR is a vertical multistage pump used in many packaged boiler feed units. This guide explains how to choose a CR model, check its temperature and material limits, and decide whether to replace the pump or the complete feed unit. Browse available models in our boiler feed pumps collection.
Why Grundfos CR Pumps Are Used for Boiler Feed
A steam boiler often needs a relatively low flow at high pressure. If the feed pump cannot keep up, the boiler may trip on its low-water cutoff. The CR uses several impellers in series to build the required head in a compact pump.
Three features make the CR a common choice for feed duty:
- High pressure in a small footprint. Several impeller stages allow the pump to develop high head. Check the working pressure rating for the exact model.
- Inline ports. The suction and discharge ports sit at the same height, so the pump can fit into a horizontal pipe run beside the receiver.
- Stainless wetted parts. The standard CR uses stainless steel impellers and chambers. CRI and CRN models also use stainless steel for the wetted sections of the pump head and base.
Our guide to single-stage vs multistage pumps explains how adding stages increases the head a pump can deliver at a given flow.
Start With Your Duty Point
The duty point combines the feed flow and the head required at that flow. Start with the boiler manufacturer’s specified feed rate, when available. Otherwise, determine flow from boiler capacity and the feed control method. Required head accounts for boiler pressure, elevation, and piping losses. See our guide on how to size a boiler feed pump and receiver for a worked example.
Use the duty point to compare the curves for individual CR models.
Matching the Duty Point to a Grundfos CR Model
In a Grundfos CR model number, the first number identifies the nominal flow size and the second identifies the stage count. Use the pump curve to confirm the actual flow and head.
- Frame (flow): small and mid-size packaged boilers usually land on the smaller frames such as the CR1, CR3 and CR5. Larger process boilers and multi-boiler plants move up to the CR10, CR15 and CR20.
- Stages (head). Select a stage count whose curve meets the required head at your design flow.
- Shutoff head. Read the head at zero flow on the pump curve. Confirm that the pump meets the boiler manufacturer’s feed pressure and shutoff head requirements.
- Working pressure. Check that the maximum inlet pressure plus the pump’s pressure rise at shutoff stays within the selected model’s working pressure rating.
Our Grundfos model numbers guide decodes every part of the type designation, and our guide on how to read a pump curve shows how to plot the duty point and find shutoff head.
Want us to check your duty point?Send us your boiler horsepower, safety valve setting, and feedwater temperature. Our team can help you narrow down the options. Call (844) 378-6771 or contact our team. |
Check NPSH at Your Feedwater Temperature
Hotter feedwater requires more pressure at the pump inlet to keep it liquid. If local pressure falls below the water’s vapor pressure, vapor bubbles form and collapse inside the pump. This is cavitation. Signs include noise, reduced performance, and pitted impellers.
Compare the available net positive suction head (NPSH) with the pump’s required NPSH at design flow. Use the margin specified in the Grundfos data booklet for the selected model.
- Raise the receiver. Every foot of water above the pump suction adds suction head. This is why feed units mount the tank on a stand.
- Keep the suction line short and full size. Fewer elbows and a full-bore strainer mean less friction loss before the pump.
- Use the operating feedwater temperature. A vented receiver near boiling may provide little suction margin. For a pressurized deaerator, account for both the vessel pressure and the water temperature.
- Check the NPSH curve at the design flow and review the highest flow the pump is expected to handle.
Our Grundfos CR troubleshooting guide covers cavitation and low inlet pressure in more detail.
Temperature Limits and the Air-Cooled Top Option
Some standard CR, CRI, and CRN configurations are rated for liquid temperatures up to 248°F (120°C). Confirm the limits for the exact model and shaft seal.
For hotter feedwater, Grundfos offers CR configurations with an air-cooled top that isolates the shaft seal from the hottest liquid. Depending on the configuration, this option can handle liquid temperatures up to 356°F (180°C). Confirm the rating before ordering.
CR, CRI or CRN for Feedwater?
These versions differ primarily in the materials that come into contact with the feedwater.
|
Version |
Wetted materials |
Typical boiler feed use |
|---|---|---|
|
CR |
Cast iron base and head, 304 stainless impellers and chambers |
Treated feedwater in typical heating and light process boilers |
|
CRI |
304 stainless steel hydraulic components and stainless steel wetted head and base |
Feed systems where you want no cast iron in contact with water |
|
CRN |
316 stainless steel hydraulic components and stainless steel wetted head and base |
Aggressive water chemistry, high-purity water or demineralized makeup |
Water treatment matters more than the pump label. If your treatment program changes chloride levels or pH, check our CR vs CRI vs CRN guide before you order, or browse the Grundfos CR series by material.
Bare Pump or Complete Boiler Feed Unit?
A replacement CR pump may be all you need if the receiver, controls, and piping are in good condition. Consider a complete feed unit if the tank is corroded, the controls are due for replacement, or you are adding a boiler.
- Replacing a failed CR pump: match the model, stages and motor from the nameplate. If the motor is healthy, a wet end may be enough. Our post on CR wet end vs complete pump replacement explains the trade-off.
- Replacing the whole system: look at packaged boiler feed units, which come with the receiver, makeup valve and controls matched to the pumps.
- Adding redundancy. A duplex arrangement can maintain feedwater supply during a pump outage when each pump can handle the required duty on its own. See simplex vs duplex pump systems.
If you are not sure where feed ends and condensate return begins, our comparison of condensate return systems vs boiler feed systems lays out what each one does.
Control Method: On/Off, Feed Valve or Variable Speed
Grundfos describes four approaches to boiler feed control. These include on/off control, a modulating feed valve, a feed valve with variable speed, and variable speed alone. On/off control is generally simpler to install. Modulation can help maintain a steadier water level. In suitable systems, a drive can reduce energy use by slowing the pump as demand falls.
Our guide to VFD pump systems vs fixed speed pumps explains when a drive can save energy. Browse the control panels and VFDs collection for available options. Account for the control method when calculating feed flow.
Before Heating Season: A Short Checklist
- Confirm boiler horsepower and safety valve setting from the nameplates.
- Record the feedwater temperature at the receiver during normal running.
- Measure the height from the receiver's low water level to the pump suction.
- Photograph the existing pump nameplate, including the full model and product number.
- Check that the suction strainer is clean and the isolation valves open fully.
For a broader pre-season list, see our boiler feed pump buying checklist.
Final Thoughts
Choose the CR frame and stage count from the required flow and head. Then verify shutoff pressure, suction conditions, temperature limits, and material compatibility for the selected model. See our Grundfos centrifugal pumps explainer for more on multistage designs, or browse our Grundfos pumps.
Frequently Asked Questions
What Grundfos pump is used for boiler feed?
The Grundfos CR vertical multistage pump is commonly used for boiler feed. CR, CRI, and CRN configurations offer different materials for feedwater conditions.
How many stages does a Grundfos boiler feed pump need?
Choose a CR frame that covers your design flow, then select the stage count that delivers the required head at that flow. Check shutoff head against the boiler manufacturer’s requirements.
What is the maximum temperature for a Grundfos CR pump?
Some standard CR, CRI, and CRN configurations handle liquids up to 248°F (120°C). Air-cooled top configurations can reach 356°F (180°C). Check the rating for the exact model and seal.
Why is my boiler feed pump cavitating?
Cavitation can occur when the available suction head is too low for the flow and feedwater temperature. Common causes include low receiver elevation, a clogged strainer, a restricted suction line, or hotter-than-expected feedwater.
Need help choosing a Grundfos boiler feed pump?Browse our Grundfos boiler feed pumps or call (844) 378-6771 for help choosing a CR model. |